Programme for Monday

(Monday,   Tuesday,   Wednesday,   Thursday,   Home)


MONDAY 11 NOVEMBER      
       
Plenary Hunter
Cardiac electromechanics
       
Keynote Beddoe Andersson Akay
Delays in radiotherapy treatment and their effects on tumour control probability Implementation of PACS - technical and human factors Neural rehabilitation engineering
       
  Dosimetry (1) Imaging (1) IEAust Young Engineers Award (1)
Papers Van Dyk Peters Kirton
Lung response in radiation therapy Integrated 3D ultrasound and MRI for neurosurgical guidance Measuring both instantaneous and passive stiffness of cardiac trabeculae in an open-ended bath
Wilkinson Abdelmalak
The aperture spread function in computed radiography The Classification of Breast Tissue Abnormalities using Electrical Impedance Measurements
Kotler Behin-Ain Chiu
Absorbed dose calculations at x-ray qualities, a viable alternative? Single photon detection in time-gated diagnostic transillumination imaging Computer simulation and design of miniaturised antenna for microwave cardiac ablation
Menzies Molteno Vanrumste
Taking the Pdis out of the TRS 398 protocol for Dmax measurements Ultra-low bandwidth teleradiology Detection of epileptiform activity in the EEG via singular value decomposition and dipole modelling
Woodings Wynn-Williams

Kvistedal

The RPH 20 mm I-125 eyeplaque Alternatives to high-bandwidth telemedicine

Identification of the mechanical constitutive properties of soft membranes

Warren Tuchyna  
Radiochromic film dosimetry for endovascular brachytherapy Implementation of a radioisotope and a radiopharmaceutical production facility for positron emission tomography  
       
  Dosimetry (2) Patient Dose in Radiology IEAust Young Engineers Award (2)
Papers Suchowerska Poletti Tan
Film dosimetry variability using Kodak X-omat-V and EDR: field size, depth, and experimental design What really happens to the radiation risk to the patient when the source to image-receptor distance is changed? Does the oculomotor control system take initial eye velocity into account when making a saccade?
Butson Warren-Forward Vanrumste
Silicon based protective dressing in radiotherapy: effects on skin dose Prediction of skin injury and organ dose in cardiac catheterisation Dipole location errors in EEG source analysis due to wrong assumptions in the volume conductor model
Tsui McLean Taylor
Clinical trial of targeted alpha therapy for melanoma: data analysis and dosimetry Initial survey of CT paediatric effective dose and thoughts on the role of the physicist in CT dose reduction Head movement recognition for power wheelchair control
Lanzon Burrage Doyle
Output for oblique electron beams The effect of eye and breast shielding in paediatric CT Using accelerometers to monitor falls in the elderly
Ebert Nicoll Kumar
Analytical modeling of a low-kV intra-operative x-ray source Film size and performance in mammography Effective retrieval of medical images for PACS using image feature extraction
Marcu McLean
Monte Carlo simulation of the radiotherapy of a virtual head and neck tumour. Report on effective dose measurements for scoliosis patients from two centres
       
CPD Murray, Bennie, Butson Le Heron, Poletti, Wallace Jones, Vanrumste
DICOM RT standard Current issues in optimization of radiation protection in diagnostic radiology Detection, enhancement, and localisation of epileptic activity in the EEG


Last Updated on 24/10/2002